Phase 3 Entanglement/Tomography Analysis Manifest¶
Date: 2026-05-20
Inputs¶
- Counts artefact:
data/phase3_entanglement_tomography/entanglement_tomography_live_ibm_fez_2026-05-20T020452Z.json - Reference CSV:
data/phase3_entanglement_tomography/entanglement_observable_rows_2026-05-07.csv - Backend:
ibm_fez - Job IDs:
d86hdk8p0eas73dkv9eg, d86hedp789is738vm7mg
Outputs¶
- JSON summary:
data/phase3_entanglement_tomography/entanglement_tomography_summary_2026-05-20_ibm_fez_pinned_full_readout.json - Observable rows:
data/phase3_entanglement_tomography/entanglement_tomography_rows_2026-05-20_ibm_fez_pinned_full_readout.csv - Observable rows SHA256:
26f9481cf008892995d9ad43e00acf1fae267a56cd5614e5fb2cf2b892bf95ff
Result Snapshot¶
- Observable rows:
54 - Mean absolute deviation from exact reference:
0.14944515917368706 - Maximum absolute deviation from exact reference:
0.4734810534982135 - Readout-mitigated mean absolute deviation from exact reference:
0.19528217448414878 - Readout-mitigated maximum absolute deviation from exact reference:
0.9912779304997331
Readout Mitigation¶
- Method:
full_correlated_readout_inverse - Calibration circuits:
16 - Boundary: full correlated readout inversion only; not a ZNE/PEC result and not a correction for basis-rotation or coherent gate errors
Boundary¶
reduced-Pauli observable analysis only; no scalable tomography, quantum advantage, or backend-general claim